POLLUTION MONITORING SYSTEMS

COD ANALYSIS SYSTEM
 
" Our COD Analysis system uses solid block digester and
Air condensors eliminating the need of water circulation with dedicated COD titrator.
It is a complete system for COD analysis ."

COD ANALYSIS SYSTEM

COD ANALYSIS SYSTEM
COD DIGESTION APPARATUS
MODEL 2015D

Model 2015D COD Digestion Apparatus is a Solid block heated
unit with provision for 15 samples at a time in 40mm dia Reaction Vessels. All the samples are heated at 150oC within ±1% accuracy with utmost uniformity of temperature. 

SALIENT FEATURES :
* Compact in Construction * No Water Circulation
* Standard APHA Method * Proven performance
* Used by many states Pollution Control Boards.

COD TITRATOR
MODEL CT-15 

Model CT-15 COD Titrator is specifically designed for titration of K2Cr2O7 against Ferrous Ammonium Sulphate. It is provided with Stand for Glass Vessel along with Magnetic Stirrer & Electrode. The results can be seen on Display directly in ppm. With Optional Printer the results can be printed in Tabular Form along with Date & Time.
SALIENT FEATURES :
* Microprocessor Based.  * Accepts 'SPECTRALAB' Digestion Vessels
* Result directly in ppm. * Can store Results upto 15 Titrations.

COD TITRATOR
Upto 15 Nos. Sample Results can be stored & recalled. With  optional printer, the printout in the tabular format is obtained as under.

Typical Report

Spectralab
COD TITRATOR
Organisation
Address

TITRATION REPORT

Smpl. No.

Form. Fact.

Dilu. Fact Blank EPml Blank-EP COD ( ppm )
01 0.0400 0001 24.7000 22.880 1.82 72.80
02 0.0400 0001 24.7000 12.270 12.43 497.20
03 0.0400 0001 24.7000 15.940 8.76 350.40
04 0.0400 0001 24.7000 22.150 2.55 102.00
05 0.0400 0001 24.7000 24.130 0.57 22.80
06 0.0400 0001 24.7000 19.630 5.07 202.80
07 0.0400 0001 24.7000 14.750 9.95 398.00
08 0.0400 0001 24.7000 19.630 5.57 222.80
09 0.0400 0001 24.7000 13.500 11.20 448.00
10 0.0400 0001 24.7000 22.890 1.81 72.40
11 0.0400 0001 24.7000 13.250 11.45 458.00
12 0.0400 0001 24.7000 20.870 3.83 153.20
13 0.0400 0001 24.7000 23.430 1.27 50.80
14 0.0400 0001 24.7000 17.150 7.55 302.00
15 0.0400 0001 24.7000 19.780 4.92 196.80


 

1] SS Holder for Glassware handling  2] FRP Water Tank  3] Aluminium Stand for Reaction Vessels
4] Aluminium Stand for Air Condensers

Holder For Glassware Handling Along With Water Tank :
This assembly is convenient for transferring all the 15 Reaction Vessels at a time from Digestion Block to Cooling Tank. FRP Water Tank  for circulation of tap water.

Aluminium Stand For Reaction Vessels & Air Condensors


SPECIFICATIONS

 
COD DIGESTION APPARATUS MODEL 2015D :
* Glassware: 15 Reaction Vessels & Air 
   Condensers.
* Temperature: 150oC ± 1%
* Capacity: 15 Samples at a time.
* Sample Size: 20ml. *Range: 0 to 500ppm
   without dilution. Further samples can be
   analysed using appropriate dilution.
* Timer: 2 Hours Timer with Buzzer
* Overall Dimensions: 475 x 295 x 200 mm
* Power Requirement: 230v 1000w
COD TITRATOR MODEL CT-15 :
* Microprocessor Based
* Modes: Blank & Sample
* Results: Directly in ppm
* Memory: Can store 15 Titration Results.
* Result Readout: On Digital Display or with
  optional Printer
* Display: Alphanumeric, Dual Line, 
  Backlighted Display.
* Key Board: Soft-touch Membrane with 19 Keys
* Date & Time of Titrations: By Real Time Clock
* Stirrer : Magnetic Stirrer
* Vessel Stand: Accepts SPECTRALAB COD 
   digestion vessels.

ORDERING INFORMATION

#  For ordering total System ask for COD ANALYSIS SYSTEM which consists of COD Digestion Apparatus, COD Auto Titrator and Holder for Glassware & Water Circulation Tank. Additionally Aluminium Stand also can be ordered.

#  For those who prefer to do the titrations
manually, order as per above except the
COD Titrator.

* Due to continuous R & D the specification & Dimensions are subject to Modifications

|        Back to Main Products Range     |       Back       |      Next      |       

Home

About Us

Client List

Contact Us 

Designed & Hosted by : MID   Promoted by : GID